Installing and Connecting the Unit
10
To connect a video source to the unit:
1. Securely connect the video cable connector (BNC) to the analog video output of the camera or
video source.
2. Connect the other cable end (BNC) to the VIDEO IN connection on the video connection panel
of the unit (see Figure 4: trk-101 Video Connection Panel).
To set the video standard for the unit via its web interface:
1. Enter the IP address of the unit in a browser. The unit’s logon window opens.
2. Login to the unit by entering your user name and password. The default user name and
password are both “admin”. The Web interface opens.
3. If your computer requires Active X installation, install it now.
4. From the Live View window, access the Camera Setup by clicking Setup → Camera →
Streaming. The Streaming window opens.
Figure 8: Web Interface Streaming Window
5. In the Video Standard field, select the video standard (PAL or NTSC).
6. Click Apply to save the setting.
Note:
If the video standard is changed, all analytic settings will be deleted.
3.2.5 Connecting the Analog Video Output to an Analog Device
Note:
The analog Video Output signal of the unit is disabled by default. Enable it if necessary using the
unit’s web interface.