Installing and Connecting the Unit
9
To change the unit’s IP address:
1. Insert the CD included in the package in your computer’s disk drive.
2. Run the configurator.exe file by clicking on the icon. The Configurator application
opens.
3. Select the unit by right-clicking on it.
Figure 7: Configurator Window
4. In the Unit network configuration section, enter the IP address, Subnet mask, and Gateway IP
address.
Note:
It is possible to set the IP address without changing the subnet.
5. If you will use a DHCP server, select the DHCP checkbox.
6. You may change the IP address for a single unit or multiple units.
To change the IP address for a single unit, select Update single. The IP address is changed.
To change the IP address for a number of units, enter the IP address of the first unit in the
series. Then select Update batch. The IP addresses are changed.
Note:
The unit and the PC must be physically connected on the same network segment.
3.2.4 Connecting the Video Source (Camera) to the Unit
The unit accepts Composite video (1Vp-p) from stationary analog cameras (Standard, Thermal, IR, and so
on).
Video connections should use a 75Ω cable and should not be longer than 30 meters (98 feet).